Silicon Labs /SiM3_NRND /SIM3U164_B /VMON_0 /CONTROL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CONTROL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (DISABLED)VREGINSEN 0 (VREGIN_IS_LOW)VREGINLI 0 (VDD_IS_BELOW_RESET)VDDRSTF 0 (VDD_IS_LOW)VDDLI 0 (DISABLED)VDDHITHEN 0 (DISABLED)VDDLIEN 0 (DISABLED)VREGINLIEN 0 (DISABLED)VMONEN

VDDLIEN=DISABLED, VREGINSEN=DISABLED, VMONEN=DISABLED, VDDHITHEN=DISABLED, VREGINLI=VREGIN_IS_LOW, VDDRSTF=VDD_IS_BELOW_RESET, VDDLI=VDD_IS_LOW, VREGINLIEN=DISABLED

Description

Module Control

Fields

VREGINSEN

VREGIN Supply Monitor Enable.

0 (DISABLED): Disable the VREGIN supply monitor.

1 (ENABLED): Enable the VREGIN supply monitor.

VREGINLI

VREGIN Low Interrupt Flag.

0 (VREGIN_IS_LOW): VREGIN is not above the interrupt threshold.

1 (VREGIN_IS_OK): VREGIN is above the interrupt threshold.

VDDRSTF

VDD Reset Threshold Status Flag.

0 (VDD_IS_BELOW_RESET): The VDD voltage is below the VDD reset threshold.

1 (VDD_IS_ABOVE_RESET): The VDD voltage is above the VDD reset threshold.

VDDLI

VDD Low Interrupt Flag.

0 (VDD_IS_LOW): The VDD voltage is below the early warning threshold.

1 (VDD_IS_OK): The VDD voltage is above the early warning threshold.

VDDHITHEN

VDD High Threshold Enable.

0 (DISABLED): Use the standard VDD thresholds.

1 (ENABLED): Use the high VDD thresholds.

VDDLIEN

VDD Low Interrupt Enable.

0 (DISABLED): Disable the VDD low interrupt.

1 (ENABLED): Enable the VDD low interrupt.

VREGINLIEN

VREGIN Low Interrupt Enable.

0 (DISABLED): Disable the VREGIN low interrupt.

1 (ENABLED): Enable the VREGIN low interrupt.

VMONEN

VDD Supply Monitor Enable.

0 (DISABLED): Disable the VDD supply monitor.

1 (ENABLED): Enable the VDD supply monitor.

Links

()